1st edition, amendment 15
Effective on 1 January 2017 until 30 June 2018
NZS 4223 Parts 1 to 4 are updated to the latest versions in B1/AS1, and the structural glass barrier requirements in Part 3 are modified.
Clause 7.4.1.3 and Figures 7.10(b) and 7.10(c) in NZS 3604 are modified to clarify the requirements (in accordance with the latest test data).
The modification in B1/VM1 on applying the hazard factor Z, to buildings with structure periods less than 1.5 seconds in the Canterbury earthquake region, is deleted.
The modification in B1/VM1 on applying a minimum risk factor for the serviceability limit state of Rs = 0.33 in the Canterbury earthquake region is deleted.
Clause 9.3.9.4.13 in NZS 3101 is modified in B1/VM1 to limit the depth of precast units to 300 mm and the overall depth to 400 mm.
The formula in B1/VM4 paragraph 3.3.2b) is corrected.