Search

Search results

Showing 11-20 of 76 results
Sorted by recency

Module 3: Identification, assessment and mitigation of liquefaction hazards

Building Code compliance > B Stability > B1 Structure > Module 3: Identification, assessment and mitigation of liquefaction hazards
Guidance for the identification, assessment and mitigation of liquefaction hazards, replacing NZGS Module 1 (July 2010).

Module 4: Earthquake resistant foundation design

Building Code compliance > B Stability > B1 Structure > Module 4: Earthquake resistant foundation design
Principles for good foundation design, up-to-date practice and implementation of Royal Commission recommendations.

Module 5: Ground improvement of soils prone to liquefaction

Building Code compliance > B Stability > B1 Structure > Module 5: Ground improvement of soils prone to liquefaction
Covers principles of ground improvement design, up-to-date practice and Canterbury earthquake recommendations.

Module 5A: Specification of ground improvement for residential properties in the Canterbury region

Building Code compliance > B Stability > B1 Structure > Module 5A: Specification of ground improvement for residential properties in the Canterbury region
Specification for ground improvement, specifically for liquefaction mitigation in residential Canterbury properties.

Module 6: Earthquake resistant retaining wall design

Building Code compliance > B Stability > B1 Structure > Module 6: Earthquake resistant retaining wall design
Covers principles of seismic design of retaining walls of a routine nature throughout New Zealand.

Rapid post disaster building usability assessment – geotechnical

Managing buildings > Managing buildings in an emergency > Rapid building assessment resources > Rapid post disaster building usability assessment – geotechnical
A field guide to promote a consistent approach to rapid building usability assessments for geotechnical professionals.

Framed buildings with precast concrete floor systems

Building Code compliance > B Stability > B1 Structure > Framed buildings with precast concrete floor systems
Assessing or designing framed buildings with precast concrete floor systems.

Securing parapets and facades on unreinforced masonry buildings

Building Code compliance > B Stability > B1 Structure > Securing parapets and facades on unreinforced masonry buildings
Guidance for building owners, councils and engineers who are required to secure parapets and facades on URM buildings.

Rockfall: Design considerations for passive protection structures

Building Code compliance > B Stability > B1 Structure > Rockfall: Design considerations for passive protection structures
Guidance on the design of passive protection structure for mitigation of rockfall risk.

Practice Advisory 19: Improving earthquake performance of non-structural elements

Building Code compliance > B Stability > B1 Structure > Practice Advisory 19
Good performance of non-structural elements in earthquakes can save lives and costs.

This information is published by the Ministry of Business, Innovation and Employment’s Chief Executive. It is a general guide only and, if used, does not relieve any person of the obligation to consider any matter to which the information relates according to the circumstances of the particular case. Expert advice may be required in specific circumstances. Where this information relates to assisting people: