Previous determinations

Determinations are made by MBIE on matters of doubt or dispute to do with building work. Rulings are legally binding, but only in relation to each case.

Previous determinations may provide some useful guidance for those faced with similar problems, but note that individual circumstances may vary.

You can also search for Determinations on Building CodeHub

Find a determination

Applying filters will narrow down your search results

Find a determination

Search results

1900 Determinations match your query
Show detailed results

2024/006: The refusal to issue a certificate of acceptance for building work associated with a dwelling

This determination considers the authority's refusal to issue a certificate of acceptance for building work associated with a dwelling, that was carried out without building consent. The authority considered that Building Code clauses B1 Structure, B2 Durability, E2 External Moisture, G2 Laundering, G9 Electricity, G12 Water Supplies and H1 Energy Efficiency were not met. The determination considers the reasons for refusal set out in the authority’s refusal letter and subsequent report.

About this document

2024/005: The authority’s decision to issue a code compliance certificate for a swimming pool

The determination considers the decision to issue a code compliance certificate for a swimming pool that required a barrier to restrict access by unsupervised young children. This determination considers the compliance of a pool barrier in relation to clause F4 of the Building Code that was in force at the time the building consent was granted.

About this document

2024/004: Regarding the refusal to carry out a final inspection and issue a code compliance certificate for a 22-year-old house

This determination considers an authority's decision to refuse to issue a Code Compliance Certificate for a building consent granted in 2000 under the former Building Act 1991. The determination will discuss the reasons given by the authority for the refusal, and how they relate to Building Code clauses B1 Structure, B2 Durability, E2 External moisture that applied in 2000.

About this document

2024/003: Whether three buildings are backcountry huts

This determination considers whether, for the purpose of compliance with the Building Code, three buildings meet the definition of 'backcountry hut' in Clause A2 Interpretation. The determination considers if the buildings are intended to provide overnight shelter to any person who may visit and who carries his or her own food, bedding, clothing, and outdoor equipment.

About this document

2024/002: The issue of a notice to fix for building work on an existing building’s foundation

This determination relates to a notice to fix where the authority considered that building work had been undertaken without a building consent and not in accordance with the building code, breaching Sections 40 and 17 of the Building Act 2004. The determination considers whether the building work was exempt from the requirement to obtain building consent, and discusses the remedies provided for in the notice.

About this document

2024/001: Regarding the issue of a dangerous and affected building notice for a residential dwelling

This determination considers an authority's decision in issuing a dangerous and affected building notice for a dwelling. The determination considers the status of the building at the time the notice was issued and takes into account all the information that is now available.

About this document

2023/043: An authority’s decision to grant a minor variation to a building consent for a change to external wall cladding

This determination considers an authority's decision to grant a minor variation to a building consent regarding the substitution of external wall cladding products. The determination considers the criteria for granting a minor variation, whether the building consent is required to reflect the change in the external wall cladding, and if a new or amended certificate of design work is required

About this document

2023/042: The compliance of a wall made of ponga logs with clauses B1 and B2 of the Building Code

This determination considers whether a wall made of ponga logs, that is located on or near a property boundary, is a 'retaining wall' and a 'building'. It also considers whether the structure complies with Building Code clauses B1 Structure and B2 Durability.

About this document

2023/041: Regarding the compliance of a kitchen ventilation system with G4.3.4 as it relates to the protection of other property

This determination considers whether the installation of a domestic kitchen ventilation system complied with Building Code Clause G4 Ventilation at the time it was installed. The determination considers whether the system’s vent is installed in a way that avoids creating a nuisance to other property in accordance with clause G4.3.4.

About this document

2023/040: An authority’s decision to refuse a waiver or modification for two isolated steps

This determination considers an authority's decision to refuse to grant, by way of building consent, a waiver or modification of Building Code clause D1.3.3(i) to authorise construction of two isolated steps in a retail unit.

About this document

This information is published by the Ministry of Business, Innovation and Employment’s Chief Executive. It is a general guide only and, if used, does not relieve any person of the obligation to consider any matter to which the information relates according to the circumstances of the particular case. Expert advice may be required in specific circumstances. Where this information relates to assisting people: